Can an Inverter Be Too Big for Your Battery System?
Always check the battery''s max discharge rate (C-rate) to avoid exceeding safe limits. When sizing for 24V or 48V systems, recalculate using the higher voltage.
Interpreting Results: Once you input the required data, the calculator will generate the recommended battery size in ampere-hours (Ah). For instance, if your power consumption is 500 watts, the usage time is 4 hours, and the inverter efficiency is 90%, the calculator might suggest a battery size of approximately 222 Ah.
Match the inverter's continuous wattage rating to the battery's discharge capacity. For a 12V 200Ah battery (2.4kWh), a 2000W inverter is ideal. Formula: Inverter Wattage ≤ (Battery Voltage × Ah Rating × 0.8). Factor in surge power needs but prioritize sustained loads.
Inverter Size: 1000W (with 2000W surge), 12V compatible Adding Load and Battery Expansion If you plan to add more batteries or higher AC loads in the future, select a modular inverter and oversize your solar system slightly to accommodate growth.
Example: If your home consumes 20 kWh/day, and you want backup for 6 hours, you'll need roughly a 5–7 kWh battery system. Your inverter and battery must work seamlessly together. - Rule of Thumb: The inverter's rated power (kW) should align with the battery's capacity (kWh). - A 5 kW hybrid inverter typically pairs well with a 5–10 kWh battery.